Loading...
  • truck Delivery when you need it
  • currency-pound Trade credit available
  • user-group Dedicated account managers
  • percent-badge Discounts for bulk orders
You are currently in the order edit mode.
APC

APC SRT 5000VA RM 230V

SKU: SRT5KRMXLI

Product highlights

  • LCD graphics display - text and mimic diagrams that display modes of operation, system parameters and alarms
  • 10/100 BaseT connection - connect the device to a network using a 10 or 100 BaseT connection
  • Battery failure notification - provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • Automatic internal bypass - supplies utility power to the connected loads in the event of a UPS power overload or fault
  • Scalable runtime - allows additional run time to be quickly added as needed
Product Description

LCD graphics display has text and mimic diagrams that display modes of operation, system parameters and alarms. Connect the device to a network using a 10 or 100 BASE-T connection. Green mode bypasses unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection. Battery failure notification provides early-warning fault analysis on batteries enabling timely preventive maintenance. Automatic internal bypass supplies utility power to the connected loads in the event of a UPS power overload or fault. Scalable runtime allows additional run time to be quickly added as needed. Intelligent battery management maximizes battery performance, life, and reliability through intelligent, precision charging.

Key Product Info

  • LCD graphics display - text and mimic diagrams that display modes of operation, system parameters and alarms
  • 10/100 BaseT connection - connect the device to a network using a 10 or 100 BaseT connection
  • Battery failure notification - provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • Automatic internal bypass - supplies utility power to the connected loads in the event of a UPS power overload or fault
  • Scalable runtime - allows additional run time to be quickly added as needed
  • Intelligent battery management - maximizes battery performance, life, and reliability through intelligent, precision charging
  • Hot-swappable batteries - ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Automatic restart of loads after UPS shutdown - automatically starts up the connected equipment upon the return of utility power
  • Temperature-compensated battery charging - prolongs battery life by regulating the charge voltage according to battery temperature
  • Automatic internal bypass - supplies utility power to the connected loads in the event of a UPS power overload or fault
  • Scalable runtime - allows additional run time to be quickly added as needed
  • Intelligent battery management - maximizes battery performance, life, and reliability through intelligent, precision charging
  • Hot-swappable batteries - ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Automatic restart of loads after UPS shutdown - automatically starts up the connected equipment upon the return of utility power
  • Temperature-compensated battery charging - prolongs battery life by regulating the charge voltage according to battery temperature
  • Plug-and-Play external batteries - ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS
  • Rack/tower convertible - protects the initial investment in the UPS when migrating from tower to rack-mount environment
  • Flash upgradeable firmware - install maintenance releases of firmware remotely using FTP
  • User-replaceable batteries - increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
  • Automatic self-test - periodic battery self-test ensures early detection of a battery that needs to be replaced
  • Predicitive failure notification - provides early-warning fault analysis ensuring proactive component replacement
  • Disconnected battery notification - warns when a battery is not available to provide backup power
  • Audible alarms - provides notification of changing utility power and UPS power conditions
  • Frequency and voltage regulation - gives higher application availability by correcting poor frequency and voltage conditions without using the battery
  • Power conditioning - protects connected loads from surges, spikes, lightning, and other power disturbances
  • Input power factor correction - minimizes installation costs by enabling the use of smaller generators and cabling
  • Generator compatible - ensures clean, uninterrupted power to protected equipment when generator power is used
  • Cold-start capable - provides temporary battery power when the utility power is out
  • Safety-agency approved - ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment

Product Features

  • LCD graphics display
    Text and mimic diagrams that display modes of operation, system parameters and alarms.
  • 10/100 BaseT ?onnection
    Connect the device to a network using a 10 or 100 BaseT connection.
  • Green mode
    Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
  • Battery failure notification
    Provides early-warning fault analysis on batteries enabling timely preventive maintenance.
  • Automatic internal bypass
    Supplies utility power to the connected loads in the event of a UPS power overload or fault.
  • Scalable runtime
    Allows additional run time to be quickly added as needed.
  • Intelligent battery management
    Maximizes battery performance, life, and reliability through intelligent, precision charging.
  • Hot-swappable batteries
    Ensures clean, uninterrupted power to protected equipment while batteries are being replaced.
  • Automatic restart of loads after UPS shutdown
    Automatically starts up the connected equipment upon the return of utility power.
  • Temperature-compensated battery charging
    Prolongs battery life by regulating the charge voltage according to battery temperature.
  • Network manageable
    Provides remote power management of the UPS over the network.
  • InfraStruXure Manager Compatible
    Enables centralized management via the APC InfraStruXure Manager.
  • SmartSlot
    Customize UPS capabilities with management cards.
  • LED status indicators
    Quickly understand unit and power status with visual indicators.
  • Serial connectivity
    Provides management of the UPS via a serial port.
  • Plug-and-Play external batteries
    Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
  • Rack/Tower convertible
    Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
  • Flash upgradeable firmware
    Install maintenance releases of firmware remotely using FTP.
  • User-replaceable batteries
    Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR).
  • Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Predicitive failure notification
    Provides early-warning fault analysis ensuring proactive component replacement.
  • Disconnected battery notification
    Warns when a battery is not available to provide backup power.
  • Audible alarms
    Provides notification of changing utility power and UPS power conditions.
  • Frequency and voltage regulation
    Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
  • Power conditioning
    Protects connected loads from surges, spikes, lightning, and other power disturbances.
  • Input power factor correction
    Minimizes installation costs by enabling the use of smaller generators and cabling.
  • Generator compatible
    Ensures clean, uninterrupted power to protected equipment when generator power is used.
  • Cold-start capable
    Provides temporary battery power when the utility power is out.
  • Resettable circuit breaker
    Easy recovery from overloads; no need to replace a fuse.

What's in the box?

  • Documentation CD
  • Installation guide
  • Rack mounting brackets
  • Rack mounting hardware
  • Rack mounting support rails
  • Temperature probe
  • Warranty card
  • Web/SNMP management card

Specification

Ports & interfaces

AC outlet types
C13 coupler,C19 coupler
Serial ports quantity
1
USB 2.0 ports quantity
1
AC outlets quantity
10 AC outlet(s)

Design

Form Factor
Rackmount
Colour of product
Black

Power

Emergency Power Off (EPO)
Y
Power supply input frequency
45/65 Hz
Output operation voltage (min)
220 V
Output power
4500 W
Surge energy rating
480 J
Output operation voltage (max)
240 V
Crest factor
3:1
Output voltage THD
3 %
Output frequency regulation
50/60 Hz
Input operation voltage (max)
275 V
Input operation voltage (min)
100 V
Output power capacity
5000 VA

Performance

Noise level
55 dB
Waveform
Sine
UPS topology
Double-conversion (Online)
Audible alarm(s)
Y

Battery

Battery recharge time
1.5 h
Typical backup time at full load
4 min
Battery Technology
Sealed Lead Acid (VRLA)
Typical backup time at half load
11.8 min

Warranty

Warranty
3 years warranty

Weight & dimensions

Package height
330 mm
Depth
719 mm
Width
432 mm
Height
130 mm
Weight
54550 g
Package weight
66860 g
Package depth
960 mm
Package width
610 mm

Operational conditions

Operating temperature (T-T)
0 - 40 ?C
Storage relative humidity (H-H)
0 - 95 %
Operating relative humidity (H-H)
0 - 95 %
Storage temperature (T-T)
-15 - 45 ?C
Non-operating altitude
0 - 15000 m
Operating altitude
0 - 3000 m

Certificates

RoHS compliance
Y
Certification
REACH, CE, CE Mark, EAC, EN/IEC 62040-1, EN/IEC 62040-2, IRAM, RCM, VDE
Product Questions (0)
Product Questions and Answers
No questions to show

Sign in or Create an account to ask a question

APC SRT 5000VA RM 230V image 1

APC SRT 5000VA RM 230V

No refurbished options available.

Quick View

Loading…